Nitrate ion selective electrode

Probe + Nitrate ISE is a half-cell ion selective electrode (ISE) ( non-integrated reference) with a robust, solid-state PVC (polymer) membrane selective to nitrate ions in solution.
This nitrate ion selective electrode (laboratory precision) is a nanotechnology device used to obtain reliable measurements in the analysis of NO3- ion concentration in aqueous solutions.
Typical nitrate reduction or denitrification processes require monitoring of nitrate production levels.
Current regulations set nitrate levels below 40 mg/L for tap water supplies.
Also fertilization with organic fertilizer is beginning to be regulated.
Use this easy, on-site device to monitor and comply with environmental regulations.
Examples of nitrate control application:

  • Environmental sciences
  • Wastewater
  • Groundwater
  • Irrigation solutions
  • Rivers and lakes
  • Nitrate contamination
  • Soil
  • Fertilizers
  • N-NO3 in plant tissue

IMPORTANT NOTE: Calibration standards are essential for creating the calibration curve in nitrate ion sensors.

SKU: S062 Categories: , ,

Product description

Ion-selective electrode for nitrate

The solid-state ion selective electrode has the advantages of being robust and miniaturized.
The nitrate ion selective electrode is composed of a mini nitrate ion selective electrode and a single ion probe that acts as an ISE holder.
The mini nitrate ISE can be exchanged for a new nitrate sensor tip or any other sensor tip available in our catalog.
The sensitivity and selectivity of the NT Sensors solid state ISEs is the same as for other ion selective electrodes.
The life expectancy of Nitrate ISE is 6 months, even if stored on a shelf or installed in a probe.
Different sensors differ by several months under the same conditions.
Recommended for use with any ion or mV meter and a reference electrode. Nitrate ions are charged particles of nitrogen and oxygen atoms that are highly reactive in nature and form a number of useful compounds.
In soils, nitrates are important plant nutrients that help promote plant growth.
Nitrates also act as electron acceptors during the respiration process, allowing fats and proteins to be broken down into usable energy for the cell.
Nitrate ions can be found in fertilizers, fertilized soil, sewage, animal waste, runoff from agricultural areas, and polluted rivers or streams.

– Half-cell probe – Mini ISE for nitrate (NO3-).
– Manual Compatible with single ions: Standard ion/mV/pH meters Recommended for use with any ion or mV meter and a reference electrode.

The nitrate ion selective electrode employs the same operating principle as standard laboratory electrodes – The potentiometry technique (ISE) is relatively inexpensive and easy to operate.
– The potentiometry technique (ISE) is relatively inexpensive and easy to operate. [av_table purpose=”tabular” pricing_table_design=”avia_pricing_default” pricing_hidden_cells=”” caption=”” responsive_styling=”avia_responsive_table” alb_description=”” id=”” custom_class=”” template_class=”” av_uid=”av-ftt7nen” sc_version=”1.0″] [av_row row_style=”avia-heading-row” av_uid=”av-flzawgv”][av_cell col_style=”avia-highlight-col” av_uid=”av-f28b1un”]Specifications[/av_cell] [av_cell col_style=”avia-center-col” av_uid=”av-elyxnvj”]Data[/av_cell][/av_row] [av_row row_style=”” av_uid=”av-e3xogov”][av_cell col_style=”avia-highlight-col” av_uid=”av-dggjnhb”]ISE range [/av_cell][av_cell col_style=”avia-center-col” av_uid=”av-dak46u7″]1 to 62.000mg/L[/av_cell][/av_row] [av_row row_style=”” av_uid=”av-ct62w8v”][av_cell col_style=”avia-highlight-col” av_uid=”av-cb0u3b3″]ISE/pH resolution[/av_cell][av_cell col_style=”avia-center-col” av_uid=”av-bstque7″]0 to 14pH is 0.01 pH 0 to 1.0ppm is 0.1ppm 1 to 9999ppm is 1ppm[/av_cell][/av_row] [av_row row_style=”” av_uid=”av-beqq3mn”][av_cell col_style=”avia-highlight-col” av_uid=”av-asm69dr”]ISE accuracy[/av_cell][av_cell col_style=”avia-center-col” av_uid=”av-a7gva5b”]±4% or 8% * In the absence of interfering ions, the accuracy can be better than 1mV, which corresponds to 4% of the measurement.[/av_cell][/av_row] [av_row row_style=”” av_uid=”av-a0wbri7″][av_cell col_style=”avia-highlight-col” av_uid=”av-9f9p2kf”]Repeatability ISE[/av_cell][av_cell col_style=”avia-center-col” av_uid=”av-963i2gv”]±10% monovalent ±20%.divalent ** Repeatability in the measurement of a standard solution after calibration.[/av_cell][/av_row] [av_row row_style=”” av_uid=”av-8g4vt1b”][av_cell col_style=”avia-highlight-col” av_uid=”av-80gtqin”]ISE/pH calibration[/av_cell][av_cell col_style=”avia-center-col” av_uid=”av-7rs70rj”]From 2 to 5 points.
Fully customizable calibration standards. [/av_cell][/av_row] [av_row row_style=”” av_uid=”av-75rzn8f”][av_cell col_style=”avia-highlight-col” av_uid=”av-o65fzz”]Power Supply[/av_cell][av_cell col_style=”avia-center-col” av_uid=”av-68noz6n”]USB – 5V -0.5A[/av_cell][/av_row] [av_row row_style=”” av_uid=”av-5uloo5b”][av_cell col_style=”avia-highlight-col” av_uid=”av-5g6ktsv”]Temperature range[/av_cell][av_cell col_style=”avia-center-col” av_uid=”av-4tmypy7″]4- 50 ºC[/av_cell][/av_row] [av_row row_style=”” av_uid=”av-4kxz58f”][av_cell col_style=”avia-highlight-col” av_uid=”av-3xiv7hb”]Interface[/av_cell][av_cell col_style=”avia-center-col” av_uid=”av-3dvz8xr”]Imacimus Windows software application ws[/av_cell][/av_row] [av_row row_style=”” av_uid=”av-34me2ov”][av_cell col_style=”avia-highlight-col” av_uid=”av-2cx75kv”]Connectivity [/av_cell][av_cell col_style=”avia-center-col” av_uid=”av-25dcmrj”]Mini USB female connector type AB [/av_cell] [/av_row] [av_row row_style=”” av_uid=”av-1mg2b8f”][av_cell col_style=”avia-highlight-col” av_uid=”av-14e7ofz”]Method[/av_cell][av_cell col_style=”avia-center-col” av_uid=”av-vvyav3″] Electrochemical / ISE[/av_cell][/av_row] [/av_table]

Single ION guide

Click here to visit the warranty page

Additional information

Weight 0,500 kg